NI-210 Professional VI Curve Tester Circuit Board Tester Tool With Two-Channel Simultaneous Display
52
Gewaarborgde Veilige Afrekening

Terugkeer items sal aanvaar word binne 40 dae wanneer dit die datum van ontvangs van die goedere is. Aangepaste items kan nie teruggegee of omgeruil word nie. Items gekoop met 'n e-geskenkbewys is slegs omruilbaar; terugbetalings is nie van toepassing nie.
Gratis Geskenk
Welkom by Roymall, jou professionele webwerf vir die aankoop van premium afdelingswinkel geskenke. Ons waardeer en waardeer jou ondersteuning, en ons wil ons dankbaarheid toon deur 'n ekstra tikkie opwinding by jou aankope te voeg. Wanneer jy by ons shop, kry jy nie net hoë gehalte produkte wat jou lewenstyl verbeter nie, maar jy sal ook 'n eksklusiewe gratis geskenk met elke bestelling wat jy plaas ontvang. Gereed om ons versameling te verken en jou perfekte geskenke te vind? Blaai deur ons keuse van premium afdelingswinkel items, plaas jou bestelling, en sien uit na die opwinding van jou gratis geskenk wat saam met jou aankoop aankom.Gestuurbeleid
Ons sal hard werk om items aan u te lewer nadat u bestellings ontvang het en sorg dat hulle veilig aankom. Afleweringsbesonderhede sal in u bevestigings-e-pos verskyn.In die meeste gevalle word bestellings binne 2 dae verwerk.Onder spesiale omstandighede sal dit soos volg vertraag: Wanneer u 'n bestelling plaas op Saterdag, Sondag of openbare vakansiedae, sal dit met 2 dae vertraag word.Normaalweg benodig dit 5-7 werksdae (Maandag tot Vrydag) sonder om deur vlugvertraging of ander omgewingsfaktore beïnvloed te word.Omdat ons versending wêreldwyd is, sal die afleveringstye van u ligging afhang, so dit mag 'n paar keer neem en wag asseblief geduldig as u in afgeleë distrikte of lande is.1. Terugkeer & Omruilingsbeleid
Ons aanvaar slegs items wat van roymall.com gekoop is. As u by ons plaaslike verspreiders of ander kleinhandelaars koop, kan u dit nie aan ons kant teruggee nie. Finale verkoop items of gratis geskenke is nie aanvaarbaar vir 'n terugkeer nie.Om in aanmerking te kom vir 'n terugkeer, moet u item ongebruik en in dieselfde toestand wees as wat u dit ontvang het. Dit moet ook in die oorspronklike verpakking wees.Nadat u terugkeerinstruksies van ons ontvang het, verpak asseblief u teruggekeerde items en los u pakkie by die plaaslike poskantoor of 'n ander koerier.Ons sal u terugkeer of omruilingsitem binne 3-5 werksdae verwerk nadat ons dit ontvang het. Die terugbetaling sal verwerk en outomaties aan u oorspronklike betaalmetode gekrediteer word.Geen teruggawes of omruilings kan aanvaar word as die produk op maat vervaardig is, insluitend pasgemaakte grootte, pasgemaakte kleur of pasgemaakte druk nie.Het u meer hulp nodig, kontak ons asseblief. service@roymall.com of Whatsapp: +86193598494712.Terugbetalingsbeleid
U sal 'n volledige terugbetaling of 100% winkelkrediet ontvang nadat ons die teruggekeerde pakkie ontvang en nagegaan het. Die terugbetaling sal verwerk en outomaties aan u oorspronklike betaalmetode gekrediteer word.Let asseblief daarop dat gestuurkoste en enige regte of fooie nie terugbetaalbaar is nie. Die ekstra gestuurkoste is nie terugbetaalbaar sodra die pakkie gestuur is nie. U is verantwoordelik om hierdie fooie te betaal en ons is nie in staat om dit te laat vaar of terug te betaal nie, selfs as die bestelling aan ons terugbesorg word.Sodra ons u teruggekeerde item ontvang en bevestig het, sal ons 'n e-pos aan u stuur om u te laat weet dat ons u teruggekeerde item ontvang het. Ons sal u ook in kennis stel van die goedkeuring of verwerping van u terugbetaling.As u enige probleme met betrekking tot die terugbetalingsproses het, kontak ons asseblief. service@roymall.com of Whatsapp: +8619359849471
Attention:
It needs to be used with an oscilloscope, and there is no high requirement on the oscilloscope, as long as it is a dual trace oscilloscope. Both analog and digital oscilloscopes can be used (low-end digital oscilloscope xy mode display effect and response speed are a bit worse).
Features:
- Dual-channel signal input
- Two channels display 3 frequencies at the same time
- 5 adjustable voltages: 3V, 10V, 15V, 20V and 60V
- Channel A, channel B, channel A+B display
- With scanning function
- Adjust the position of channel B for easy comparison and measurement
- AC/DC trigger output with adjustable amplitude and width
Summary of the VI Tester:
1. ASA test application characteristics:
Analog Signature Analysis is a fault detection technique widely used in electronic circuit board. Has the following application characteristics:
1.1. It does not involve the circuit principle and does not need the circuit to be in working condition, so it can be used for fault detection of the circuit board without drawings and data, which is out of the equipment (without online testing).
1.2. There is no need to power up the circuit board, which is relatively safer.
1.3. It does not involve the function of the components on the circuit board, so no matter what type of device the circuit is composed of, digital, analog, mixed digital-analog, known functions, unknown (such as dedicated, programmable), etc. can be tested.
1.4. It is tested on a circuit-by-circuit node (device pin), and is basically not limited by the packaging of components on the circuit board. Since a single device can be regarded as the simplest circuit board circuit, ASA technology can also be used to detect the quality of large-scale, complex or integrated devices with unknown functions. In fact, due to limited conditions, ASA is the only way for many users to detect such devices. In addition, when ASA is used to detect the function of discrete components, it is also convenient and intuitive.
2. The basic test principle of ASA:
As far as the basic detection principle is concerned, the ASA test can be seen as a natural extension of the multimeter detection method.
For circuit board without drawings, the most commonly used fault detection method is as follows: first use a multimeter to measure the resistance of the device pins on the circuit board (actually the circuit node) to ground; and then compare it with the corresponding device pins on the failed circuit board. Compare the ground resistance, and judge whether there is a fault on the node according to the difference. From node to specific components need to be manually determined. This method is simple, easy to use and effective. Many people have used this method to repair complex and expensive circuit board.
The main reason for the failure detection rate of this method is that the multimeter can only detect the resistance under 1.5V (multimeter battery voltage), and the ground resistance of the semiconductor device pin changes with the voltage-the resistance under different voltages may not be same. For example, a TTL device pin has a soft breakdown at 2.5V, resulting in a large leakage current. Such failures cannot be detected.
Imagine you have dozens or hundreds of multimeters, and the battery voltage of each meter is different-the voltage range includes the working voltage of the device. For each pin, use these tables to test and compare all of them, so that the above-mentioned faults will be detected. This is the principle of ASA testingu2014comparison in a voltage range, not just at a voltage point.
Package Included:
1 x Set of IV Curve Tester
Note:
- Battery is not included.
It needs to be used with an oscilloscope, and there is no high requirement on the oscilloscope, as long as it is a dual trace oscilloscope. Both analog and digital oscilloscopes can be used (low-end digital oscilloscope xy mode display effect and response speed are a bit worse).
Features:
- Dual-channel signal input
- Two channels display 3 frequencies at the same time
- 5 adjustable voltages: 3V, 10V, 15V, 20V and 60V
- Channel A, channel B, channel A+B display
- With scanning function
- Adjust the position of channel B for easy comparison and measurement
- AC/DC trigger output with adjustable amplitude and width
Summary of the VI Tester:
1. ASA test application characteristics:
Analog Signature Analysis is a fault detection technique widely used in electronic circuit board. Has the following application characteristics:
1.1. It does not involve the circuit principle and does not need the circuit to be in working condition, so it can be used for fault detection of the circuit board without drawings and data, which is out of the equipment (without online testing).
1.2. There is no need to power up the circuit board, which is relatively safer.
1.3. It does not involve the function of the components on the circuit board, so no matter what type of device the circuit is composed of, digital, analog, mixed digital-analog, known functions, unknown (such as dedicated, programmable), etc. can be tested.
1.4. It is tested on a circuit-by-circuit node (device pin), and is basically not limited by the packaging of components on the circuit board. Since a single device can be regarded as the simplest circuit board circuit, ASA technology can also be used to detect the quality of large-scale, complex or integrated devices with unknown functions. In fact, due to limited conditions, ASA is the only way for many users to detect such devices. In addition, when ASA is used to detect the function of discrete components, it is also convenient and intuitive.
2. The basic test principle of ASA:
As far as the basic detection principle is concerned, the ASA test can be seen as a natural extension of the multimeter detection method.
For circuit board without drawings, the most commonly used fault detection method is as follows: first use a multimeter to measure the resistance of the device pins on the circuit board (actually the circuit node) to ground; and then compare it with the corresponding device pins on the failed circuit board. Compare the ground resistance, and judge whether there is a fault on the node according to the difference. From node to specific components need to be manually determined. This method is simple, easy to use and effective. Many people have used this method to repair complex and expensive circuit board.
The main reason for the failure detection rate of this method is that the multimeter can only detect the resistance under 1.5V (multimeter battery voltage), and the ground resistance of the semiconductor device pin changes with the voltage-the resistance under different voltages may not be same. For example, a TTL device pin has a soft breakdown at 2.5V, resulting in a large leakage current. Such failures cannot be detected.
Imagine you have dozens or hundreds of multimeters, and the battery voltage of each meter is different-the voltage range includes the working voltage of the device. For each pin, use these tables to test and compare all of them, so that the above-mentioned faults will be detected. This is the principle of ASA testingu2014comparison in a voltage range, not just at a voltage point.
Package Included:
1 x Set of IV Curve Tester
Note:
- Battery is not included.